Abstract:Objective: To explore the value of transthoracic echocardiography(TTE) on observation the catheter tip of the internal jugular vein long-termcatheter in hemodialysis patients. Methods: From January 2016 to July 2017, 52 hemodialysis patients with the internal jugular vein long-termcatheter undertook TTE and X-ray, to observe the catheter tip, including its position, and other complication such as thrombosis. Results: In the 52 cases, catheter tips of 49 cases could be observed clearly by TEE(94.2%). Cathetertip localization rate was 87.8%(43/49), ectopic rate was 12.2%(6/49); while catheter tips of 48 cases could be observed clearly by X-ray(92.3%), the cathetertip localization rate was 89.6%(43/48), and ectopic rate was 10.4%(5/48). There was no statistically significant difference(P>0.05). Kappa test showed a better consistence(P<0.05). Thrombosis was found in fourteen catheter tips by TTE, while none could be found by X-ray. All the ectopic severe cases were retreated to ideal position under the guidance of TTE, and the success rate was 100%. For the thrombosis patients, treatment of thrombolysis was guided. Conclusion: TTE can clearly display catheter tip, observe its position and the presence of thrombus. It can help to adjust ectopic catheter tip and evaluate thrombolysis effect. It’s noninvasive, convenient, safe, rapid and accurate. It shows an important clinical value.
罗 丽,庞广保,赵毅兰,甘小玲,沈 洁,潘 艳. 经胸超声心动图在观察长期颈内静脉血透导管尖端中的应用[J]. 中国临床医学影像杂志, 2018, 29(12): 866-868.
LUO Li, PANG Guang-bao, ZHAO Yi-lan, GAN Xiao-ling, SHEN Jie, PAN Yan. The value of transthoracic echocardiography on observation of the catheter tip of the internal jugular vein long-termcatheter in hemodialysis patients. JOURNAL OF CHINA MEDICAL IMAGING, 2018, 29(12): 866-868.
[1]宋士霞. 静脉留置针的应用及护理[J]. 中华医学研究杂志,2003,3(2):15-16.
[2]袁芳,刘映红,李铮,等. 超声引导下颈内静脉留置永久性双腔导管在维持性血液透析患者中的应用[J]. 中南大学学报:医学版,2014,39(1):61-66.
[3]王梅,杨云方,左力,等. 持续性颈内静脉插管在维持血液透析患者中的应用[J]. 中华内科杂志,1999,38(6):403.
[4]Jain A, McNamara PJ, Ng E, et al. The use of targeted neonatal echocardiography to confirm placement of peripherally inserted central catheters in neonates[J]. Am J Perinatol, 2012, 29(2): 101-106.
[5]陈霞,吴宏,黄小妹. 尖端定位方法的应用与思考[J]. 大家健康,2017,11(3):87.
[6]刘春丽,刘腊根,陈传英,等. 置管实时尖端定位方法的现状及进展[J]. 护理学报,2017,24(9):39-42.
[7]Schummer W, Schummer C, Schelenz C, et al. Modified ECG-guidance for optimal central venous catheter tip positioning. A transesophageal echocardiography controlled study[J]. Anaesthesist, 2005, 54(10): 983-990.
[8]Yoon SZ, Shin TJ, Kim HS, et al. Depth of a central venous catheter tip: length of insertion guideline for pediatric patients[J]. Acta Anaesthesiol Scand, 2006, 50(3): 355-357.
[9]耿斌,张桂珍. 临床儿童及胎儿超声心动图学[M]. 天津:天津科技翻译出版有限公司,2015:25-27.
[10]Ohki Y, Tabata M, Kuwashima M, et al. Ultrasonographic detection of very thin percutaneous central venous catheter in neonates[J]. Acta Pediatr, 2000, 89(11): 1381-1384.
[11]任聃,段云友,刘禧,等. 彩色多普勒超声与数字减影血管造影对比评价不同节段下肢深静脉血栓的诊断价值[J]. 中华超声影像学杂志,2009,18(2):146-148.