Abstract:Objective: To investigate the relationship between the respiratory rate and the scanning pitch when performing chest CT scan and evaluate their effect on image quality and radiation dose. Methods: Eighty-five patients were divided into group A and B randomly. According to their respiratory rate, patients in group A were divided into A1 and A2 group; patients in group B were divided into B1 and B2 group. In group A, high-pitch mode CT scan was performed; in group B, low-pitch mode CT scan was performed. The CTDIvol and DLP were recorded, and the image quality was evaluated subjectively and objectively. Results: Image quality of group A was better than that of group B; the difference was more obvious in A1 and B1 group; the CTDIvol was not significantly different in group A and group B, but the mean DLP value was 18.5% higher in group A than group B. Conclusion: Low-pitch mode CT scan was more suitable for low RRs patients when performing chest CT scan, that will reduce radiation dose while maintaining preferable image quality. Low-pitch mode CT scan was more suitable for low RRs patients when performing chest CT scan, which will reduce radiation dose while maintaining preferable image quality.
边传振,张 楠,刘 鹏. 呼吸频率及螺距对儿童胸部CT图像质量和辐射剂量的影响[J]. 中国临床医学影像杂志, 2019, 30(7): 468-471.
BIAN Chuan-zhen, ZHANG Nan, LIU Peng. The effect of respiratory rate and pitch on chest CT image quality and radiation dose of children. JOURNAL OF CHINA MEDICAL IMAGING, 2019, 30(7): 468-471.
[1]Bakhshi S, Radhakrishnan V, Sharma P, et al. Pediatric nonlymphoblastic non-Hodgkin lymphoma: baseline, interim, and post-treatment PET/CT versus contrast-enhanced CT for evaluation—a prospective study[J]. Radiology, 2012, 262(3): 956-968.
[2]Malviya S, Voepel-Lewis T, Eldevik OP, et al. Sedation and general anaesthesia in children undergoing MRI and CT: adverse events and outcomes[J]. Br J Anaesth, 2000, 84(6): 743-748.
[3]Deak PD, Langner O, Lell M, et al. Effects of adaptive section collimation on patient radiation dose in multisection spiral CT[J]. Radiology, 2009, 252(1): 140-147.
[4]Larson DB, Wang LL, Podberesky DJ, et al. System for verifiable CT radiation dose optimization based on image quality. Part Ⅰ. Optimization model[J]. Radiology, 2013, 269(1): 167-176.
[5]vander Molen AJ, Geleijns J. Overranging in multisection CT: quantification and relative contribution to dose-comparison of four 16-section CT scanner[J]. Radiology, 2007, 242(1): 208-216.
[6]Bastos MD, Lee EY, Strauss KJ, et al. Motion artifact on high-resolution CT images of pediatric patients: comparison of volumetric and axial CT methods[J]. AJR, 2009, 193(5): 1414-1418.
[7]Kelly DM, Hasegawa I, Borders R, et al. High-resolution CT using MDCT: comparison of degree of motion artifact between volumetric and axial methods[J]. AJR, 2012, 182(3): 757-759.
[8]曾宪春,陈静,王玉权,等. 超大螺距Turbo Flash扫描模式在学龄前儿童胸部检查中不用镇静剂的可行性[J]. 中国医学影像技术,2017,33(8):1221-1225.
[9]田为中,张波,窦小峰,等. 双源CT大螺距螺旋扫描序列在无镇静儿童胸部CT平扫中的临床应用价值[J]. 中华放射学杂志,2014,48(3):252-254.
[10]罗松,郑玲,张龙江,等. 超低剂量CTA研究专题·大螺距模式下智能最佳管电压调节结合迭代重建技术在CT胸主动脉成像中的图像质量和辐射剂量评价[J]. 放射学实践,2016,29(6):597-600.
[11]Kim SH, Choi YH, Cho HH, et al. Comparison of image quality and radiation dose between high-pitch mode and low-pitch mode spiral chest CT in small uncooperative children: the effect of respiratory rate[J]. Eur Radiol, 2016, 26(4): 1149-1158.
[12]刘一,晏子旭,吴晓峰,等. 螺距的选择对胸腹主动脉夹层320层CT成像质量的影响[J]. 放射学实践,2011,26(3):350-353.
[13]Lucaya J, Piqueras J, García-Pena P, et al. Low-dose high-resolution CT of the chest in children and young adults: dose, cooperation, artifact incidence, and image quality[J]. AJR, 2000, 175(4): 985-992.
[14]Gordic S, Desbiolles L, Sedlmair M, et al. Optimizing radiation dose by using advanced modelled iterative reconstruction in high-pitch coronary CT angiography[J]. Eur Radiol, 2016, 26(2): 459-468.
[15]袁肖娜,高知玲,马文东,等. 对比分析容积CT剂量指数与体型特异性的剂量评估在估算腹部CT扫描辐射剂量中的差异[J]. 中华放射医学与防护杂志,2016,36(1):74-77.